Belden-1504A 22 AWG x 2P(Double-Pair) Stereo Audio, Control and Instrumentation Cable , PVC - PVC 語音立體音響, 通訊, 儀表控制電纜
1504A
 |
|
Multi-Conductor - Double-Pair Cable
22 AWG stranded (19x34) TC conductors, PVC insulation, dual twisted pairs, overall Beldfoil® shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket in zip-cord construction. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
1504A A5QU1000 |
1,000 FT |
32.000 LB |
RED & GREEN |
|
2 BONDED #22 FS PR PVC FR PVC |
1504A A5Q2000 |
2,000 FT |
64.000 LB |
RED & GREEN |
C |
2 BONDED #22 FS PR PVC FR PVC |
1504A G04U1000 |
1,000 FT |
32.000 LB |
RED & PURPLE |
|
2 BONDED #22 FS PR PVC FR PVC |
1504A J77U1000 |
1,000 FT |
32.000 LB |
USE 061 |
|
2 BONDED #22 FS PR PVC FR PVC |
1504A 053U1000 |
1,000 FT |
32.000 LB |
RED & GRAY |
|
2 BONDED #22 FS PR PVC FR PVC |
1504A 0531000 |
1,000 FT |
33.000 LB |
RED & GRAY |
|
2 BONDED #22 FS PR PVC FR PVC |
1504A 0532000 |
2,000 FT |
64.000 LB |
RED & GRAY |
C |
2 BONDED #22 FS PR PVC FR PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
2 |
22 |
19x34 |
TC - Tinned Copper |
|
Total Number of Conductors: |
4 |
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
PVC - Polyvinyl Chloride |
.010 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
24 |
7x30 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cable
Overall Nominal Diameter: |
0.143 x 0.286 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Black & Red |
2 |
Black & Red |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-30°C To +60°C |
UL Temperature Rating: |
60°C |
Bulk Cable Weight: |
30 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
25 lbs. |
Min. Bend Radius/Minor Axis: |
1.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CM |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
10/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
13.7 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
18 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
2.9 Amps per conductor @ 25°C |
|
Notes (Overall)
Notes: |
The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. |
|