Belden 82641 24 AWG x 1P stranded TC CMP, FEP Insulation.60°C 2芯鐵氟龍耐高溫声音音響, 通訊, 儀表控制電纜
82641
 |
|
Multi-Conductor - Single-Pair Cable
24 AWG stranded (7x32) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
82641 877U1000 |
1,000 FT |
9.000 LB |
NATURAL |
|
1 PR #24 FEP FS FLMRST |
82641 8771000 |
1,000 FT |
10.000 LB |
NATURAL |
C |
1 PR #24 FEP FS FLMRST |
|
Notes: |
|
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
1 |
24 |
7x32 |
TC - Tinned Copper |
|
Total Number of Conductors: |
2 |
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
FEP - Fluorinated Ethylene Propylene |
.006 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
24 |
7x32 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name |
Outer Jacket Material |
Nom. Wall Thickness (in.) |
Flamarrest® |
LS PVC - Low Smoke Polyvinyl Chloride |
.014 |
|
Overall Cable
Overall Nominal Diameter: |
0.106 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Black & Red |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
0°C To +60°C |
Bulk Cable Weight: |
8 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
16 lbs. |
Min. Bend Radius/Minor Axis: |
1.250 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMP |
CEC/C(UL) Specification: |
CMP |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
24.1 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
17 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
2.2 Amps per conductor @ 25°C |
|
|