Belden-8451 22 AWG x 1P (300V 75°C) PE-PVC jacket. 2芯声音音響, 通訊, 儀表控制電纜
8451
 |
|
Multi-Conductor - Single-Pair Cable
22 AWG stranded (7x30) TC conductors, polypropylene insulation, paper wrap, twisted pair, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
8451 008U1000 |
1,000 FT |
16.000 LB |
GRAY |
|
2 #22 PP SHLD PVC FR |
8451 008U500 |
500 FT |
8.500 LB |
GRAY |
|
2 #22 PP SHLD PVC FR |
8451 0081000 |
1,000 FT |
16.000 LB |
GRAY |
C |
2 #22 PP SHLD PVC FR |
8451 008500 |
500 FT |
8.000 LB |
GRAY |
|
2 #22 PP SHLD PVC FR |
8451 010U1000 |
1,000 FT |
16.000 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 010U500 |
500 FT |
8.500 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 010100 |
100 FT |
2.200 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 0101000 |
1,000 FT |
16.000 LB |
BLACK |
C |
2 #22 PP SHLD PVC FR |
8451 01010000 |
10,000 FT |
160.000 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 01015000 |
15,000 FT |
240.000 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 010500 |
500 FT |
8.000 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
8451 0105000 |
5,000 FT |
80.000 LB |
BLACK |
|
2 #22 PP SHLD PVC FR |
|
Notes: |
|
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
1 |
22 |
7x30 |
TC - Tinned Copper |
|
Total Number of Conductors: |
2 |
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
PP - Polypropylene |
.008 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
Beldfoil® (Z-Fold®) |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
22 |
7x30 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cable
Overall Nominal Diameter: |
0.138 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Black & Red |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +75°C |
Bulk Cable Weight: |
15 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
27 lbs. |
Min. Bend Radius/Minor Axis: |
1.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMR |
CEC/C(UL) Specification: |
CMG |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1666 Vertical Shaft |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
14.5 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
14.1 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
2.9 Amps per conductor @ 25°C |
|
Notes (Overall)
Notes: |
Unique paper separator facilitates jacket stripping. |
|