| Belden-9462 22 AWG x 1P- Audio, Control and Instrumentation Cable , PVC - PVC 語音音響, 通訊, 儀表控制電纜
9462
 |
|
Multi-Conductor - Audio, Control and Instrumentation Cable
22 AWG stranded (7x30) tinned copper conductors, PVC insulation, twisted pair, overall Beldfoil® shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket. |
For more Information
Please call
1-800-Belden1 |

Click here for Certificate
| Item ## |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 9462 060U1000 |
1,000 FT |
21.000 LB |
CHROME |
|
2 #22 PVC FS PVC |
| 9462 060U500 |
500 FT |
11.000 LB |
CHROME |
|
2 #22 PVC FS PVC |
| 9462 060100 |
100 FT |
2.700 LB |
CHROME |
|
2 #22 PVC FS PVC |
| 9462 0601000 |
1,000 FT |
21.000 LB |
CHROME |
C |
2 #22 PVC FS PVC |
| 9462 060500 |
500 FT |
10.500 LB |
CHROME |
|
2 #22 PVC FS PVC |
| 9462 0605000 |
5,000 FT |
105.000 LB |
CHROME |
C Z |
2 #22 PVC FS PVC |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs |
AWG |
Stranding |
Conductor Material |
| 1 |
22 |
7x30 |
TC - Tinned Copper |
|
| Total Number of Conductors: |
2 |
Insulation
Insulation Material:
| Insulation Material |
Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
0.014 |
|
Outer Shield
Outer Shield Material:
| Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
| Beldfoil® (Z-Fold®) |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
| AWG |
Stranding |
Drain Wire Conductor Material |
| 22 |
7x30 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
Nom. Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
.035 |
|
Overall Cable
| Overall Nominal Diameter: |
0.186 in. |
Pair
Pair Color Code Chart:
| Number |
Color |
| 1 |
Black & Red |
|
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-30°C To +80°C |
| UL Temperature Rating: |
80°C (UL AWM Style 2464) |
| Bulk Cable Weight: |
19 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
27 lbs. |
| Min. Bend Radius/Minor Axis: |
2 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CMG |
| CEC/C(UL) Specification: |
CMG |
| AWM Specification: |
UL Style 2464 (300 V 80°C) |
| EU Directive 2011/65/EU (ROHS II): |
Yes |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
| UL Flame Test: |
UL1685 FT4 Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 16 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
| Current |
| 3 Amps per conductor @ 25°C |
|
|