1694D
 | | Coax - Dual RG-6/U Type Precision Low Loss Serial Digital Video coax Dual RG-6/U type, (2) 18 AWG solid .040" bare copper conductors, gas-injected foam HDPE insulation, Duofoil® plus tinned copper braid shield (95% coverage), inner PVC jackets, overall PVC jacket. | For more Information please call
1-800-Belden1 |
Click here for Certificate
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 1694D 0101000 | 1,000 FT | 131.000 LB | BLACK | C | 2 #18 PE SH PVC FRPVC PARA PVC | | 1694D 010500 | 500 FT | 66.000 LB | BLACK | | 2 #18 PE SH PVC FRPVC PARA PVC |
|
| Notes: | |
C = CRATE REEL PUT-UP. |
Usage (Overall)
| Suitable Applications: | Video Mult. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | | 2 | 18 | Solid | BC - Bare Copper | 0.040 |
|
| Total Number of Conductors: | 2 |
Insulation
Insulation Material:
| Insulation Material | Dia. (in.) | | Gas-injected FHDPE - Foam High Density Polyethylene | .180 |
|
Inner Shield
Inner Shield Material:
| Layer # | Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | | 1 | Duofoil® | Tape | Aluminum Foil-Polyester Tape-Aluminum Foil | 100 | | 2 | | Braid | TC - Tinned Copper | 95 |
|
Inner Jacket
Inner Jacket Material:
| Inner Jacket Material | Nom. Dia. (in.) | | PVC - Polyvinyl Chloride | .275 |
|
Inner Jacket Color Code Chart:
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | | PVC - Polyvinyl Chloride |
|
Overall Cable
| Overall Nominal Diameter: | 0.344 x 0.618 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -40°C To +75°C |
| UL Temperature Rating: | 60°C |
| Non-UL Temperature Rating: | 75°C |
| Bulk Cable Weight: | 124 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 177 lbs. |
| Min. Bend Radius/Minor Axis: | 3.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: | CMR |
| CEC/C(UL) Specification: | CMG |
| EU Directive 2011/65/EU (ROHS II): | Yes |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 04/09/2010 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
| UL Flame Test: | UL1666 Vertical Shaft |
Suitability
| Suitability - Outdoor: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 6.4 |
|
Nom. Inner Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 2.800 |
|
Nom. Attenuation:
| Freq. (MHz) | Attenuation (dB/100 ft.) | | 1.000 | 0.240 | | 3.580 | 0.440 | | 5.000 | 0.520 | | 7.000 | 0.610 | | 10.000 | 0.710 | | 67.500 | 1.650 | | 71.500 | 1.690 | | 88.500 | 1.860 | | 100.000 | 1.950 | | 135.000 | 2.240 | | 143.000 | 2.300 | | 180.000 | 2.570 | | 270.000 | 3.170 | | 360.000 | 3.690 | | 540.000 | 4.600 | | 720.000 | 5.380 | | 750.000 | 5.500 | | 1000.000 | 6.420 | | 1500.000 | 7.990 | | 2000.000 | 9.370 | | 2250.000 | 10.010 | | 3000.000 | 11.780 | | 4500.000 | 15.700 |
|
Max. Operating Voltage - UL:
| Other Electrical Characteristic 1: | Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination. |
| Other Electrical Characteristic 2: | Return Loss tested in accordance with ASTM D-4566 paragraph 45.3, using a 75 Ohm fixed bridge and termination. |
Minimum Structural Return Loss:
| Start Freq. (MHz) | Stop Freq. (MHz) | Min. SRL (dB) | | 5.000 | 1600.000 | 23.000 | | 1600.000 | 4500.000 | 21.000 |
|
Sweep Test
| Sweep Testing: | Sweep tested 5 MHz to 4.5 GHz. |
Revision Number: 1 Revision Date: 05-10-2013