8142
 |
|
Multi-Conductor - Parallel Digital Video
28 AWG stranded (7x36) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® + TC braid shield (65% coverage), TC drain wire, PVC jacket. |
For more Information
please call
1-800-Belden1 |
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 8142 0601000 |
1,000 FT |
68.000 LB |
CHROME |
C |
12PR + 1#28 FHDPE SH PVC |
| 8142 060500 |
500 FT |
33.500 LB |
CHROME |
C |
12PR + 1#28 FHDPE SH PVC |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Conductors |
# Pairs |
AWG |
Stranding |
Conductor Material |
| 1 |
12 |
28 |
7x36 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
| Insulation Trade Name |
Insulation Material |
| Datalene® |
FPE - Foam Polyethylene |
|
Outer Shield
Outer Shield Material:
| Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
| 1 |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape w/Shorting Fold |
100 |
| 2 |
|
Braid |
TC - Tinned Copper |
65 |
|
Outer Shield Drain Wire AWG:
| AWG |
Stranding |
Drain Wire Conductor Material |
| 28 |
7x36 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
| PVC - Polyvinyl Chloride |
|
Overall Cabling
| Overall Nominal Diameter: |
0.389 in. |
Pair
Pair Color Code Chart:
| Number |
Color |
| 1 |
White/Blue & Blue/White |
| 2 |
White/Orange & Orange/White |
| 3 |
White/Green & Green/White |
| 4 |
White/Brown & Brown/White |
| 5 |
White/Gray & Gray/White |
| 6 |
Red/Blue & Blue/Red |
| 7 |
Red/Orange & Orange/Red |
| 8 |
Red/Green & Green/Red |
| 9 |
Red/Brown & Brown/Red |
| 10 |
Red/Gray & Gray/Red |
| 11 |
Black/Blue & Blue/Black |
| 12 |
Black/Orange & Orange/Black |
| Single Conductor |
Gray |
|
Pair Lay Length & Direction:
| Lay Length (in.) |
Twists/ft. (twist/ft) |
| 0.920 |
10.400 |
|
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-30°C To +80°C |
| UL Temperature Rating: |
80°C (UL AWM Style 2919) |
| Bulk Cable Weight: |
65 lbs/1000 ft. |
| Min. Bend Radius (Install)/Minor Axis: |
3 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CL2 |
| AWM Specification: |
UL Style 2919 (30 V 80°C) |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
| UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 65 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 3.1 |
|
Max. Operating Voltage - UL:
| Voltage |
| 30 V RMS (UL AWM Style 2919) |
|
Max. Operating Voltage - Non-UL:
Max. Recommended Current:
| Current |
| 0.7 Amps per conductor @ 25°C |
|
|