| 商品編號: Belden-9493
Triad - Power Limited Tray Cable 300 Volts |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 新網頁55 9493 Triad - Power Limited Tray Cable 300 Volts |  | | Total # Cond. | # Triads | 3 | 1 | AWG | Stranding | Type | Insulation | Insulation Thickness (in.) | Shield | 18 | (19x30) | TC - Tinned Copper | PVC - Polyvinyl Chloride | .01400 | Unshielded | | Jacket | Jacket Thickness (in.) | Nom. Core OD (in.) | Nom. OD (in.) | Nom. Cond. DCR (Ohms/M') | Nom. Cap. (pF/ft) | PVC - Polyvinyl Chloride | .0370 | .1680 | .2420 | 5.960 | 31.800 | | | Description | Multi-Conductor, 1 triad (3 conductors), 18 AWG, stranded (19x30) TC - Tinned Copper conductors, PVC - Polyvinyl Chloride insulation, Unshielded, sunlight resistant PVC - Polyvinyl Chloride jacket. Applicable Specifications: UL PLTC, ITC, CMG, C(UL) CMG, FT4, IEEE 1202. Flame Resistance: CSA FT4 Flame Test. Industrial Automation & Process Control Cables. Instrumentation Cables. These cables are suitable for installation in wet or dry locations. Cable jackets are sunlight resistant, impervious to moisture and vapor penetration, and non-propagating. | | | | | | | | | | | | | | | | Disclaimer: Great effort is made to ensure the accuracy of the information presented, but errors or omissions may occur. This listing of information is presented as a courtesy and does not ensure that a product with these specifications is available. Specification and availability should be confirmed with a call to our sales representative or to Customer Service. Have a question? Call us at 1-800-BELDEN-1 or send us a comment | | |
| | | |
| | 新網頁56 18 AWG (19 X#30) TINNED COPPER, PVC INSULATION, 3 CONDUCTOR | CABLE, PVC JACKET WITH NYLON RIPCORD. | II. ELECTRICAL CHARACTERISTICS: | -------------------------- | MAX. OPERATING VOLTAGE: 300 VOLTS | MAX. CONTINUOUS CURRENT PER | CONDUCTOR @ 25 DEG. C: 9 AMPS | NOM. BREAKDOWN VOLTAGE BETWEEN | CONDUCTORS (SHORT TERM): 20,000 VRMS | ADJACENT CONDRS. @ 1 KHZ: 31.8 PF/FT | ADJACENT CONDRS.: .15 MICRO-H/FT. | NOM. CONDUCTOR DC RESISTANCE | @ 20 DEG. C: 5.96 OHMS/1000 FT. | NOM. INSULATION RESISTANCE | @ 500 VOLTS DC: 2500MOHMS/1000 FT. | III. PHYSICAL CHARACTERISTICS: | TEMPERATURE RATING: -30 TO +105 DEG. C | JACKET MATERIAL: PVC(CHROME-SUNLIGHT RES) | MAXIMUM PULLING TENSION: 62 LBS | NOM. WEIGHT/1000 FT.: 35.9 LBS. | APPLICABLE SPECIFICATION: UL PLTC OR ITC OR CMG | FLAME RESISTANCE: CSA FT4 FLAME TEST | COLOR CODE: BLACK, RED, WHITE | |
| |
|
|