8641
 |
|
Multi-Conductor - Single-Pair Cable
24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket. |
For more Information
please call
1-800-Belden1 |
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 8641 060U1000 |
1,000 FT |
14.000 LB |
CHROME |
|
1 #24 FS PR PE PVC |
| 8641 060U500 |
500 FT |
7.500 LB |
CHROME |
|
1 #24 FS PR PE PVC |
| 8641 060100 |
100 FT |
2.000 LB |
CHROME |
|
1 #24 FS PR PE PVC |
| 8641 0601000 |
1,000 FT |
14.000 LB |
CHROME |
C |
1 #24 FS PR PE PVC |
| 8641 0602000 |
2,000 FT |
28.000 LB |
CHROME |
C |
1 #24 FS PR PE PVC |
| 8641 060500 |
500 FT |
7.000 LB |
CHROME |
|
1 #24 FS PR PE PVC |
| 8641 0605000 |
5,000 FT |
65.000 LB |
CHROME |
|
1 #24 FS PR PE PVC |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs |
AWG |
Stranding |
Conductor Material |
| 1 |
24 |
7x32 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
| Insulation Material |
Wall Thickness (in.) |
| PE - Polyethylene |
.016 |
|
Outer Shield
Outer Shield Material:
| Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
| Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Outer Shield Drain Wire AWG:
| AWG |
Stranding |
Drain Wire Conductor Material |
| 24 |
7x32 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
Nom. Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
.025 |
|
Overall Cabling
| Overall Nominal Diameter: |
0.168 in. |
Pair
Pair Color Code Chart:
| Number |
Color |
| 1 |
Black & Clear |
|
Pair Lay Length & Direction:
| Lay Length (in.) |
Twists/ft. (twist/ft) |
| 1.500 |
8.000 |
|
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-20°C To +80°C |
| UL Temperature Rating: |
60°C (UL AWM Style 2092) |
| Bulk Cable Weight: |
12.100 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
11 lbs. |
| Min. Bend Radius (Install)/Minor Axis: |
1.700 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CM |
| CEC/C(UL) Specification: |
CM |
| AWM Specification: |
UL Style 2092 (300 V 60°C) |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
| UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
| Plenum Number: |
88641, 82641 |
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 25 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 14.6 |
|
Max. Operating Voltage - UL:
| Voltage |
| 300 V RMS (UL AWM Style 2092) |
|
Max. Recommended Current:
| Current |
| 2.2 Amps per conductor @ 25°C |
|