8777
 |
|
Multi-Conductor - Shielded Twisted Pair Cable
22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs individually Beldfoil® Shielded (100% coverage), 22 AWG stranded tinned copper drain wire, PVC jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
8777 060U1000 |
1,000 FT |
40.000 LB |
CHROME |
|
3 SH PR #22 PP PVC |
8777 060U500 |
500 FT |
20.500 LB |
CHROME |
|
3 SHLD PR #22 PP PVC |
8777 060100 |
100 FT |
4.600 LB |
CHROME |
|
3 SHLD PR #22 PP PVC |
8777 0601000 |
1,000 FT |
42.000 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
8777 06010000 |
10,000 FT |
450.000 LB |
CHROME |
C Y |
3 SHLD PR #22 PP PVC |
8777 0601640 |
1,640 FT |
67.240 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
8777 060250 |
250 FT |
11.000 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
8777 0603280 |
3,280 FT |
137.760 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
8777 060500 |
500 FT |
21.000 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
8777 0605000 |
5,000 FT |
210.000 LB |
CHROME |
C |
3 SHLD PR #22 PP PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
3 |
22 |
7x30 |
TC - Tinned Copper |
.030 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
PP - Polypropylene |
.050 |
|
Inner Shield
Inner Shield Material:
Layer # |
Inner Shield Trade Name |
Type |
Inner Shield Material |
Coverage (%) |
1 |
Beldfoil® |
Tape |
Aluminum-Polyester |
100 |
2 |
|
Tape |
Polyester |
100 |
|
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: |
7x30 |
Inner Shield Drain Wire Conductor Material: |
TC - Tinned Copper |
Outer Shield
Outer Shield Material:
Outer Shield Material |
Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cabling
Overall Nominal Diameter: |
0.273 x 0.000 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Black & Red |
2 |
Black & White |
3 |
Black & Green |
|
Pair Lay Length & Direction:
Lay Length (in.) |
Twists/ft. (twist/ft) |
1.750 |
6.850 |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +80°C |
UL Temperature Rating: |
80°C (UL AWM Style 2919) |
Bulk Cable Weight: |
40.800 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
79 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
2.750 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CM |
AWM Specification: |
UL Style 2919 (30 V 80°C) |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Plenum Number: |
88777, 87777, 82777 |
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
15.0 |
|
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: |
10.600 Ohm/1000 ft |
Max. Operating Voltage - UL:
Voltage |
30 V RMS (UL AWM Style 2919) |
300 V RMS (CM) |
|
Max. Recommended Current:
Current |
2 Amps per conductor @ 25°C |
|