商品編號: Belden-9402
Belden 9402 UL2464 300V Awg22 x2Pair Audio, Control and Instrumentation Cable 廣播聲音音響, 儀表電腦控制電纜
20 AWG stranded (7x28) TC conductors, semi-rigid PVC insulation, twisted pairs, individually shielded w/Beldfoil® (100% coverage), 22 AWG stranded TC drain wire, overall PVC jacket.
9402
 |
|
Multi-Conductor - Audio, Control and Instrumentation Cable
20 AWG stranded (7x28) TC conductors, semi-rigid PVC insulation, twisted pairs, individually shielded w/Beldfoil® (100% coverage), 22 AWG stranded TC drain wire, overall PVC jacket. |
For more Information
please call
1-800-Belden1 |
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 9402 060U500 |
500 FT |
26.000 LB |
CHROME |
|
2 FS PR #20 PVC PVC |
| 9402 0601000 |
1,000 FT |
52.000 LB |
CHROME |
C |
2 FS PR #20 PVC PVC |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs |
AWG |
Stranding |
Conductor Material |
| 2 |
20 |
7x28 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
| Insulation Material |
Wall Thickness (in.) |
| S-R PVC - Semi-Rigid Polyvinyl Chloride |
.010 |
|
Inner Shield
Inner Shield Material:
| Inner Shield Trade Name |
Type |
Inner Shield Material |
Coverage (%) |
| Beldfoil® (Z-Fold®) |
Tape |
Aluminum Foil-Polyester Tape |
100 |
|
Inner Shield Drain Wire AWG:
| Inner Shield Drain Wire Stranding: |
19x34 |
| Inner Shield Drain Wire Conductor Material: |
TC - Tinned Copper |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
Nom. Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
.041 |
|
Overall Cabling
| Overall Nominal Diameter: |
0.300 in. |
Pair
Pair Color Code Chart:
| Number |
Color |
| 1 |
Red & Black |
| 2 |
Green & White |
|
Pair Lay Length & Direction:
| Lay Length (in.) |
Twists/ft. (twist/ft) |
| 1.750 |
6.900 |
|
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-20°C To +80°C |
| UL Temperature Rating: |
80°C (UL AWM Style 2464) |
| Bulk Cable Weight: |
46.500 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
72 lbs. |
| Min. Bend Radius (Install)/Minor Axis: |
3 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CMG |
| CEC/C(UL) Specification: |
CMG |
| AWM Specification: |
UL Style 2464 (300 V 80°C) |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 9.3 |
|
| Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: |
12 Ohm/1000 ft |
Max. Operating Voltage - UL:
| Voltage |
| 300 V RMS (UL AWM Style 2464) |
|
Max. Recommended Current:
| Current |
| 3.1 Amps per conductor @ 25°C |
|
|
|
|
|
|