1. (太平洋/華新/華榮)電線電纜區
    600V-380度耐熱電線電纜-1
    600V-380度耐熱電線電纜-2
    600V-380度耐熱電線電纜-3
    600V-840度耐熱電線電纜-1C
    600V-840度耐熱電線電纜-3C
    600V-840度耐熱電線電纜-4C
    LSFH-XLPE低煙無毒電線
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Belden-工業(Thermocouple-Cable)補償導線

    Belden-Thermocouple Extension Cables  Industrial Grade Sunlight- and Oil-Resistant Jackets 工業級防曬防油溫度補償導線(延長線)
    看原圖
    5448501




    商品編號: BELDEN-Thermocouple-Wire-E

    Belden-Thermocouple Extension Cables Industrial Grade Sunlight- and Oil-Resistant Jackets 工業級防曬防油溫度補償導線(延長線)


    UL Instrumentation Cable
    Thermocouple Extension Cables
    Industrial Grade Sunlight- and Oil-Resistant Jackets

    20 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
    Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • PVC Jacket

    Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket

    16 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
    Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket




    ★★★★商品說明★★★★

    UL Instrumentation Cable
    Thermocouple Extension Cables and Thermocouple Wire — Overview
    Construction Thermocouple
    Extension Cable

    Conductor material determined by the
    thermocouple extension wire type. FEP
    or PVC insulated with FEP or PVC jacket.
    Nylon rip cord included in all PVC-jacketed
    thermocouple extension cables. Communication
    wire included on all multi-pair,
    PVC constructions — 22 AWG (7x30) bare
    copper orange PVC insulation.
     

    NOTE: The temperature ranges in Table A
    are applicable only to the thermocouple
    conductors and not to the cable. The cable
    must never be exposed to temperatures
    higher than the maximum temperature
    ratings shown in Table B.

    Application
    Unshielded
    Parallel non-shielded extension wire may
    be utilized in low noise environments
    when recommended by the instrument
    manufacturer.
     

    Overall Shield
    Recommended, except in areas where high
    voltage and current sources create excessive
    noise interference. The Beldfoil® shield with
    drain wire provides 100% coverage for
    maximum shield effectiveness.
    Individually Shielded
    Individually shielded pairs are recommended
    for use in applications where optimum noise
    rejection is required.
     

    PVC Insulated, PVC JacketedCable Specifications
    ● UL Subject 13
    ● UL 1685 (UL 1581) Vertical Tray Flame
    Test comparable to IEEE 383-1974
    (70,000 BTU) Flame Test
    ● ANSI/MC 96.1–1982
    ● NEC CMG
    ● NEC Type PLTC Listed, which is
    approved for cable tray use in Class 1,
    Division 2, hazardous areas and
    non-hazardous areas, cable trays,
    raceways, conduit and supported
    by messenger wires.
    ● NEC Type ITC Listed, which is approved
    for cable tray use, raceways hazardous
    locations according to Articles 501, 502,
    503 and 504; or as aerial on a cable
    messenger, and under raised floors in
    control rooms and rack rooms where
    arranged to prevent damage to the cable.
    Usages are allowed based on qualified
    persons servicing all installations.
    ● PVC/PVC constructions are CMG, FT4,
    IEEE 1202 and IEEE 383-2003 rated,
    and meet ICEA T-29-520 Flame Test.
    ● UL 1277 TC versions approved for use
    in Class 1 trays available as special.
     

    Shielded Twisted Pair
    (FEP insulated, FEP jacketed cable specifications)

    ● UL Subject 13
    ● NFPA 262 (UL 910 Steiner Tunnel Flame
    Test) comparable to FT6 Flame Test
    ● ANSI/MC 96.1–1982
    ● NEC Type CL3P/PLTC Listed, which is
    approved for use in ducts, plenums and
    other space used for environmental air.
    ● UL 1277 TC versions approved for use
    in Class 1 trays available as special.
     

    Thermocouple Wire
    Conductor material determined by the
    thermocouple type. FEP insulated and
    jacketed flat constructions.
    FEP thermocouple wire is impervious to
    chemical attack and is flame retardant.