商品編號: Belden-123092A
Belden-123092A Aluminum Interlocked Armor Quad Shielded Coax for ControlNet Applications 可直接埋設波浪狀鋁管鎧裝電纜
Belden® ControlBus cables are Low-loss RG-6/U Type Coaxes.They meet the
high-speed, time-critical requirements necessary for the operation of ControlNet™
factory-floor systems.
With a Continuously Corrugated Aluminum Armored Product
123092A
 |
|
Coax - ControlNet™ Quad Shielded Coax
18 AWG solid bare copper-covered steel conductor, foam polyethylene insulation, Duobond IV® quad shield (100% coverage), PVC inner jacket, aluminum interlocked armor, PVC sunlight-resistant outer jacket. |
For more Information
please call
1-800-Belden1 |
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
123092A J221000 |
1,000 FT |
150.000 LB |
BLUE, STRONG |
|
3092A ALUM ARMOR PVC |
123092A J225000 |
5,000 FT |
850.000 LB |
BLUE, STRONG |
|
3092A ALUM ARMOR PVC |
123092A 0101000 |
1,000 FT |
150.000 LB |
BLACK |
|
3092A ALUM ARMOR PVC |
123092A 0102000 |
2,000 FT |
310.000 LB |
BLACK |
|
3092A ALUM ARMOR PVC |
123092A 0105000 |
5,000 FT |
850.000 LB |
BLACK |
|
3092A ALUM ARMOR PVC - SPECIAL |
|
Usage (Overall)
Suitable Applications: |
ControlNet™, Modbus II, Industrial Coax |
Physical Characteristics (Overall)
Conductor
AWG:
# Coax |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
18 |
Solid |
BCCS - Bare Copper Covered Steel |
.040 |
|
Insulation
Insulation Material:
Insulation Material |
Dia. (in.) |
FPE - Foam Polyethylene |
.180 |
|
Inner Jacket
Inner Jacket Material:
Inner Jacket Material |
PVC - Polyvinyl Chloride |
|
Outer Shield
Outer Shield Material:
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Bonded Duofoil® |
Tape |
Bonded Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
2 |
|
Braid |
AL - Aluminum |
60 |
3 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape-Aluminum Foil |
100 |
4 |
|
Braid |
AL - Aluminum |
40 |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Armor
Overall Cabling
Overall Nominal Diameter: |
0.600 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-30°C To +75°C |
Bulk Cable Weight: |
142 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
162 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
7.300 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CMG, HL |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
10/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 FT4 Loading |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
28.0 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.6 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1 |
.35 |
2 |
.38 |
5 |
.45 |
10 |
.59 |
20 |
.86 |
50 |
1.37 |
100 |
1.97 |
200 |
2.82 |
300 |
3.48 |
400 |
4.04 |
|
Max. Operating Voltage - UL:
Minimum Structural Return Loss:
Description |
Freq. (MHz) |
Start Freq. (MHz) |
Stop Freq. (MHz) |
Min. SRL (dB) |
|
|
5 |
50 |
23 |
|
Notes (Overall)
Notes: |
ControlNet is a ControlNet International trademark. |
|