| 商品編號: Belden-1245A2
1245A2 Paired - Category 3 Unbonded-Pair Cable
24 AWG solid bare copper conductors, twisted pairs, plenum, low-smoke PVC insulation, see color code chart (below), gray PVC jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | DESCRIPTION: 24 AWG solid bare copper conductors, twisted pairs, plenum, low-smoke PVC insulation, see color code chart (below), gray PVC jacket. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Pairs: 4 Total Number of Conductors: 8 AWG: 24 Stranding: Solid Conductor Material: BC - Bare Copper INSULATION : Insulation Material: LS PVC - Low Smoke Polyvinylchloride Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green Number Color 4 White/Brown Stripe & Brown OUTER SHIELD : Outer Shield Material: Unshielded OUTER JACKET : Outer Jacket Material Trade Name: Flamarrest® Outer Jacket Material: LS PVC - Low Smoke Polyvinyl Chloride OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .200 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -20°C To +75°C Bulk Cable Weight: 20 lbs/1000 ft. Max. Recommended Pulling Tension: 25 lbs. Min. Bend Radius (Install): 2 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CMP, UL444 CEC/C(UL) Specification: CMP IEEE Specification: 802.3 10BaseT, 100BaseT4 EU CE Mark (Y/N): Yes TIA/EIA Specification: 568-B.2 Category 3 Other Specification: NEMA WC-63 Category 3, UL verified to TIA/EIA-568-B.2, Category 3 FLAME TEST : UL Flame Test: NFPA 262 CSA Flame Test: FT6 PLENUM/NON-PLENUM : Plenum (Y/N): Y Non-Plenum Number: 1229A1 ELECTRICAL CHARACTERISTICS : Nom. Mutual Capacitance @ 1 KHz: 19 pF/ft Maximum Capacitance Unbalance (pF/100 m): 330 pF/100 m Nominal Velocity of Propagation: 61 % Nominal Delay: 1.5 ns/ft Maximum Conductor DC Resistance @ 20 Deg. C: 9.38 Ω/100 m Maximum DCR Unbalance @ 20 Deg. C: 5 % Max. Operating Voltage - UL: 300 V RMS ELECTRICAL CHARACTERISTICS - PREMISE : Premise Cable Electricals: Frequency (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. Structural Return Loss (dB) Fitted Impedance (Ohms) 1 2.56 41.0 No Spec 12.0 100 ± 15% 4 5.58 32.0 No Spec 12.0 100 ± 15% 10 9.71 26.0 No Spec 12.0 100 ± 15% 16 13.10 23.0 No Spec 9.96 100 ± 15% NOTES : Notes: Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 3. PUT-UPS AND COLORS: Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 1245A2 009U1000 4 PR #24 FLRST FLRST U1000 23 WHITE
|
| |
|
|