| | 3612
 | | Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable 23 AWG solid bare copper conductors, polyolefin insulation, X-Spline center member, rip cord, PVC jacket. | For more Information please call
1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 3612 003A1000 | 1,000 FT | 26.000 LB | ORANGE | C | 4 PR #23 PO FRPVC | | 3612 004A1000 | 1,000 FT | 26.000 LB | YELLOW | C | 4 PR #23 PO FRPVC | | 3612 0041000 | 1,000 FT | 24.000 LB | YELLOW | C | 4 PR #23 PO FRPVC | | 3612 0042500 | 2,500 FT | 57.500 LB | YELLOW | | 4 PR #23 PO FRPVC | | 3612 005A1000 | 1,000 FT | 26.000 LB | GREEN, DARK | C | 4 PR #23 PO FRPVC | | 3612 0051000 | 1,000 FT | 24.000 LB | GREEN, DARK | C | 4 PR #23 PO FRPVC | | 3612 006A1000 | 1,000 FT | 26.000 LB | BLUE, LIGHT | C | 4 PR #23 PO FRPVC | | 3612 0061000 | 1,000 FT | 24.000 LB | BLUE, LIGHT | C | 4 PR #23 PO FRPVC | | 3612 0062500 | 2,500 FT | 57.500 LB | BLUE, LIGHT | | 4 PR #23 PO FRPVC | | 3612 007A1000 | 1,000 FT | 26.000 LB | VIOLET | C | 4 PR #23 PO FRPVC | | 3612 008A1000 | 1,000 FT | 26.000 LB | GRAY | C | 4 PR #23 PO FRPVC | | 3612 0081000 | 1,000 FT | 24.000 LB | GRAY | C | 4 PR #23 PO FRPVC | | 3612 009A1000 | 1,000 FT | 26.000 LB | WHITE | C | 4 PR #23 PO FRPVC | | 3612 0091000 | 1,000 FT | 24.000 LB | WHITE | C | 4 PR #23 PO FRPVC | | 3612 0092500 | 2,500 FT | 57.500 LB | WHITE | | 4 PR #23 PO FRPVC | | 3612 010A1000 | 1,000 FT | 26.000 LB | BLACK | C | 4 PR #23 PO FRPVC | | 3612 0101000 | 1,000 FT | 24.000 LB | BLACK | C | 4 PR #23 PO FRPVC |
|
| Notes: | | C = CRATE REEL PUT-UP. |
Usage (Overall) | Suitable Applications: | Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments |
Physical Characteristics (Overall) Conductor AWG: | # Pairs | AWG | Stranding | Conductor Material | | 4 | 23 | Solid | BC - Bare Copper |
|
Insulation Insulation Material: | Insulation Material | | Polyolefin |
|
Outer Shield Outer Shield Material: | Outer Shield Material | | Unshielded |
|
Outer Jacket Outer Jacket Material: | Outer Jacket Material | Nom. Wall Thickness (in.) | | PVC | 0.018 |
|
Overall Cabling | Overall Cabling Fillers: | X-Spline Center Member |
| Overall Nominal Diameter: | 0.235 in. |
Pair Pair Color Code Chart: | Number | Color | | 1 | White/Blue Stripe & Blue | | 2 | White/Orange Stripe & Orange | | 3 | White/Green Stripe & Green | | 4 | White/Brown Stripe & Brown |
|
Mechanical Characteristics (Overall) | Storage Temperature Range: | -30°C To +75°C |
| Installation Temperature Range: | +5°C To +50°C |
| Operating Temperature Range: | 0°C To +75°C |
| UL Temperature Rating: | 75°C |
| Bulk Cable Weight: | 28 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 45 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 1 in. |
Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs | NEC/(UL) Specification: | CMR |
| CEC/C(UL) Specification: | CMR |
| Other Standards: | 11801 Category 6 |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 04/03/2009 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
| Telecommunications Standards: | Category 6 - TIA 568.B.2-1 |
| Other Specification: | UL Verified to Category 6 |
Flame Test | UL Flame Test: | UL1666 Vertical Riser |
Suitability Plenum/Non-Plenum Electrical Characteristics (Overall) Nom. Mutual Capacitance: | Maximum Capacitance Unbalance (pF/100 m): | 330 |
Nominal Velocity of Propagation: Maximum Delay: | Freq. (MHz) | Delay (ns/100 m) | | 100.000 | 537.600 |
|
Typical Delay Skew: Maximum Conductor DC Resistance: | DCR @ 20°C (Ohm/100 m) | | 7.700 |
|
Max. Operating Voltage - UL: Maximum DCR Unbalanced: | DCR Unbalance @ 20°C (%) | | 5.000 |
|
Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: | Freq. (MHz) | Max. Attenuation (dB/100 m) | Min. NEXT (dB) | Min. PSNEXT (dB) | Min. ACR (dB) | Min. PSACR (dB) | Min RL (dB) | Min. SRL (dB) | | 0.772 | 1.800 | 81.00 | 79.00 | 79.2 | 77.2 | | | | 1 | 2.000 | 79.31 | 77.31 | 77.3 | 75.3 | 20.000 | 27.0 | | 4 | 3.700 | 70.28 | 68.28 | 66.6 | 64.6 | 23.000 | 27.0 | | 8 | 5.200 | 65.77 | 63.77 | 60.6 | 58.6 | 24.500 | 27.0 | | 10 | 5.800 | 64.31 | 62.31 | 58.5 | 56.5 | 25.000 | 27.0 | | 16 | 7.400 | 61.25 | 59.25 | 53.9 | 51.9 | 25.000 | 27.0 | | 20 | 8.300 | 59.80 | 57.80 | 51.5 | 49.5 | 25.000 | 27.0 | | 25 | 9.300 | 58.35 | 56.35 | 49.1 | 47.1 | 24.300 | 26.0 | | 31.25 | 10.400 | 56.89 | 54.89 | 46.5 | 44.5 | 23.600 | 25.1 | | 62.5 | 15.000 | 52.38 | 50.38 | 37.4 | 35.4 | 21.500 | 22.1 | | 100 | 19.300 | 49.31 | 47.31 | 30.0 | 28.0 | 20.800 | 20.0 | | 155 | 24.600 | 46.46 | 44.46 | 21.9 | 19.9 | 19.500 | 18.1 | | 200 | 28.300 | 44.80 | 42.80 | 16.5 | 14.5 | 18.700 | 17.0 | | 250 | 32.100 | 43.35 | 41.35 | 11.2 | 9.2 | 18.000 | 16.0 | | 300 | 35.600 | 42.16 | 40.16 | 6.5 | 4.5 | 17.500 | 15.2 | | 350 | 38.900 | 41.15 | 39.15 | 2.3 | 0.3 | 17.000 | 14.6 | | 400 | 42.000 | 40.28 | 38.28 | | | 16.600 | 14.0 | | 450 | 45.000 | 39.52 | 37.52 | | | 16.200 | 13.5 | | 500 | 47.900 | 38.83 | 36.83 | | | 15.900 | 13.0 | | 550 | 50.600 | 38.21 | 36.21 | | | 15.600 | 12.6 | | 600 | 53.300 | 37.64 | 35.64 | | | 15.400 | 12.2 | | 650 | 55.900 | 37.12 | 35.12 | | | 15.100 | 11.9 |
|
Premise Cable Electrical Table 2: | Freq. (MHz) | Input (Unfitted) Imp. (Ohms) | Min. ACRF (dB) | Min. PSACRF (dB) | | .772 | | 75.0 | 72.0 | | 1 | 100 ± 15 | 72.8 | 69.8 | | 4 | 100 ± 15 | 60.8 | 57.8 | | 8 | 100 ± 15 | 54.7 | 51.7 | | 10 | 100 ± 15 | 52.8 | 49.8 | | 16 | 100 ± 15 | 48.7 | 45.7 | | 20 | 100 ± 15 | 46.8 | 43.8 | | 25 | 100 ± 15 | 44.8 | 41.8 | | 31.25 | 100 ± 15 | 42.9 | 39.9 | | 62.5 | 100 ± 15 | 36.9 | 33.9 | | 100 | 100 ± 15 | 32.8 | 29.8 | | 155 | 100 ± 22 | 28.9 | 25.9 | | 200 | 100 ± 22 | 26.8 | 23.8 | | 250 | 100 ± 32 | 24.8 | 21.8 | | 300 | 100 ± 32 | 23.3 | 20.3 | | 350 | 100 ± 32 | 21.9 | 18.9 | | 400 | 100 ± 32 | 20.8 | 17.8 | | 450 | 100 ± 32 | 19.7 | 16.7 | | 500 | 100 ± 32 | 18.8 | 15.8 | | 550 | 100 ± 32 | 18.0 | 15.0 | | 600 | 100 ± 32 | 17.2 | 14.2 | | 650 | 100 ± 32 | 16.5 | 13.5 | | | | | |
|
Premise Cable Electrical Table 3: | Frequency (MHz) | Min. TCL (dB) | Min. ELTCTL (dB) | | .772 | 40.0 | 37.2 | | 1 | 40.0 | 35.0 | | 4 | 40.0 | 23.0 | | 8 | 40.0 | 16.9 | | 10 | 40.0 | 15.0 | | 16 | 38.0 | 10.9 | | 20 | 37.0 | 9.0 | | 25 | 36.0 | 7.0 | | 31.25 | 35.1 | | | 62.5 | 32.0 | | | 100 | 30.0 | | | 155 | 28.1 | | | 200 | 27.0 | | | 250 | 26.0 | |
|
Notes (Overall) | Notes: | Jacket sequentially marked at 2 ft/1m. intervals. US Patents # 5424491, 5734126, 6074503, 6596944, 7339116 . Third party verified to TIA/EIA-568-B.2-1, Category 6. Values above 350MHz are for engineering information only. |
|
| |
|
|