7804R
 |
|
Composite - SMPTE 311M HDTV Cable
4 power conductors, 2 SM fibers w/24 and 20 AWG stranded (7x32 and 19x32) TC conductors, PVC insulation, TC braid shield (95% coverage), Belflex® jacket. |
For more Information
please call
1-800-Belden1 |

Click here for Certificate
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 7804R B591000 |
1,000 FT |
96.000 LB |
BLACK, MATTE |
C |
COMPOSITE CAMERA CABLE |
| 7804R B591640 |
1,640 FT |
152.520 LB |
BLACK, MATTE |
C |
COMPOSITE CAMERA CABLE |
| 7804R B593280 |
3,280 FT |
314.880 LB |
BLACK, MATTE |
C |
COMPOSITE CAMERA CABLE |
| 7804R B59500 |
500 FT |
47.500 LB |
BLACK, MATTE |
C |
COMPOSITE CAMERA CABLE |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Usage (Overall)
| Suitable Applications: |
SMPTE 311M Camera Cable |
Multi Conductor
Physical Characteristics
Conductor
AWG:
| # Conductors |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
| 2 |
24 |
7x32 |
TC - Tinned Copper |
0.024 |
| 4 |
20 |
19x32 |
TC - Tinned Copper |
0.037 |
|
Insulation
Insulation Material:
| Insulation Material |
Dia. (in.) |
AWG |
| PVC - Polyvinyl Chloride |
0.063 |
20 |
| PVC - Polyvinyl Chloride |
0.050 |
24 |
|
Insulation Color Code Chart:
| Number |
Color |
Description |
| 1 |
Red |
24 AWG |
| 2 |
Gray |
24 AWG |
| 3 |
White |
20 AWG |
| 4 |
Black |
20 AWG |
| 5 |
White/Black |
20 AWG |
| 6 |
Black/White |
20 AWG |
|
Electrical Characteristics
Nom. Conductor DC Resistance:
| Description |
DCR @ 20°C (Ohm/1000 ft) |
| 24 AWG |
23.300 |
| 20 AWG |
8.800 |
|
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 3.500 |
|
Fiber
Physical Characteristics
| Fiber Type: |
Non-Dispersion Shifted, Single Mode/125/900 Micron |
| Mode Field Diameter @ 1310nm: |
9.5 +/-1 microns |
| Clad Diameter: |
125 microns |
| Core-clad Concentricity Error: |
< to="" 1=""> |
| Primary Coating Material: |
Acrylate |
| Buffer Tube Diameter: |
900 microns |
| Buffer Tube Material: |
PVC - Polyvinyl Chloride |
Buffer Tube Color Code Chart:
| Number |
Color |
| 1 |
Blue |
| 2 |
Yellow |
|
Optical Characteristics
| Maximum Attenuation @ 1310nm: |
0.8 dB/km |
Physical Characteristics (Overall)
Conductor
Outer Shield
Outer Shield Material:
| Type |
Outer Shield Material |
Coverage (%) |
| Braid |
TC - Tinned Copper |
95.000 |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Trade Name |
Outer Jacket Material |
| Belflex® |
PVC Blend - Polyvinyl Chloride Blend |
|
Strength Member
| Overall Strength Member Diameter: |
.089 |
| Strength Member Material: |
302 Stainless Steel |
Overall Cable
| Overall Nominal Diameter: |
0.362 in. |
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-40°C To +75°C |
| Bulk Cable Weight: |
80 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
450 lbs. |
| Min. Bend Radius/Minor Axis: |
2.500 in. |
| Flex Cycle Rating: |
UL1581, Sec. 1582: 15,000 Cycles @ 3.6 |
| Crush Resistance: |
Compression, FOTP-41: 397 lbs. |
| Impact Resistance: |
FOTP-25: 20 Cycles @ 1.32 lbs. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CMR |
| CEC/C(UL) Specification: |
CMG |
| EU Directive 2011/65/EU (ROHS II): |
Yes |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
07/01/2005 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
| Other Specification: |
SMPTE 311M |
Flame Test
| UL Flame Test: |
UL1666 Vertical Shaft |
Suitability
| Suitability - Indoor: |
Yes |
| Suitability - Outdoor: |
Yes |
| Suggested Connectors: |
SMPTE 304M Connectors |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
| Other Electrical Characteristic 1: |
Auxillary Conductors: DC Loop Resistance - 30 Ohms/km nom. (9.1 Ohms/1000ft.) Min. Insullation Resistance - 10, 000 Megaohms x km Dielectric Strength - 1750 V RMS. Signal Conductors: DC Loop Resistance - 150 Ohms/km nom. (45.7 Ohms/1000 ft.) Insulation Resistance - 10, 000 Megaohms/1000 ft. Dielectric Strength: 1750 V RMS |
Notes (Overall)
| Notes: |
Bend Radius is based upon (FOTP-37) @ 20°C. Plenum version and other conductor counts/diameters available by special order. |