商品編號: Belden-5240FR
Belden-(5240FR, 5201FR) 16 AWG x 1Pair PLTC-CI 2-hour Fire Rated/Industrial Control Shutdown Cable 防火災耐火阻燃2小時 2芯隔離工業控制關機電纜
Survivability, Survivability from Attack by Fire, Fire Alarm Circuit Integrity, CI, Survivability by NFPA72, Sim to MI, Similar to Mineral Insulated, FPLR-CI, Emergency Circuits, Notification Devices, Fire Pumps, 2 hour fire rating, Emergency Pumps, Emergency Shutdown Systems
5240FR
|
|
Multi-Conductor - Commercial Applications
16 AWGS stranded (7x24) bare copper conductors, ceramifiable silicone insulation, Beldfoil® shield (100% coverage), drain wire, FRPE (low smoke non-halogen) jacket. Sequential footage marking every two feet. |
For more Information
please call
1-800-Belden1 |
Click here for Certificate
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
|
Usage (Overall)
Suitable Applications: |
Survivability, Survivability from Attack by Fire, Fire Alarm Circuit Integrity, CI, Survivability by NFPA72, Sim to MI, Similar to Mineral Insulated, FPLR-CI, Emergency Circuits, Notification Devices, Fire Pumps, 2 hour fire rating, Emergency Pumps, Emergency Shutdown Systems |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
1 |
16 |
7x24 |
BC - Bare Copper |
|
Total Number of Conductors: |
2 |
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
Silicone Rubber |
.034 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
Beldfoil® |
Tape |
Polyester Tape-Aluminum Foil |
100 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
18 |
7x26 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
Nom. Wall Thickness (in.) |
FRPE - Flame Retardant Polyethylene |
.045 |
|
Overall Cable
Overall Cabling Color Code Chart:
Number |
Color |
1 |
Black |
2 |
White |
|
Overall Nominal Diameter: |
0.350 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +105°C |
UL Temperature Rating: |
105°C |
Bulk Cable Weight: |
86 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
93 lbs. |
Min. Bend Radius/Minor Axis: |
3.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
FPLR-CI, ITC, PLTC |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
03/20/2006 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1666 Riser |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Suitability - Burial: |
Yes |
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
4.0 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
5.1 |
|
Max. Operating Voltage - UL:
|