Cable structure Tinned copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5 Core insulation of rubber compound type GI1 to DIN VDE 0207 part 20 Core identification to DIN VDE 0293 - up to 5 cores coloured - from 6 cores, black with continuous white numbering Cores stranded (without elongated central core) with max. lay-length of 8x Ø over the stranding layers Textile tape Textile braiding as protection against torsion, embedded in inner filling sheath Outer sheath of neoprene compound type 5GM2 to DIN VDE 0207 part 21 Sheath colour black Tinned copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5 Core insulation of rubber compound type GI1 to DIN VDE 0207 part 20 Core identification to DIN VDE 0293 - up to 5 cores coloured - from 6 cores, black with continuous white numbering Cores stranded (without elongated central core) with max. lay-length of 8x Ø over the stranding layers Textile tape Textile braiding as protection against torsion, embedded in inner filling sheath Outer sheath of neoprene compound type 5GM2 to DIN VDE 0207 part 21 Sheath colour black "> Properties Designed and developed for horizontal drum-operation Permissible running speed up">
Due to the neoprene outer sheath, the cables is resistant against ozone and radiation, oils, acids, fats, gazoline, solvents and chemicals
During the installation and operation the tensile stress on conductor may not increase 15 N/mm²
Accelaration not more than 0,4 m/s²
During operation, 1-2 convolutions should remain on the operating drum
In case of high mechanical stress, especially of high dynamic tensile stress result high accelaration, the permissible stress must be defined in each case
Tests
Behaviour in fire to DIN VDE 0482-332-1-2 DIN EN 60332-2-1, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Oil resistant acc. to DIN VDE 0473-811-404,DIN EN 60811-404
Note
G = with green-yellow conductor
AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Application
Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional stress, for building machinery, conveyors, shifts and cranes. They are used as robust and all weather resistant cables of roughest operations in mining and in flexible handling equipment and railway motors. The cables are suitable for outdoor installation in dry, damp and wet places as well in open air. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for reeling cables. Please read the installation instructions. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.