    A- XLP/High-strength Airbag layer/PVC ICEA S-95-658/NEMA WC70 and UL 44 Type XHHW-2 90°C, 600V 3芯PRYSMIAN CABLES & SYSTEMS 控制電纜


    For installation in wet and dry locations in accordance with NEC. May be directly buried or embedded in concrete. For installation on cable trays, troughs, metal racks, aerial
    installation and continuous rigid cable supports in accordance with NEC. Suitable for variable frequency drive applications (VFD). Suitable for vertical riser applications.
    Suitable for Class 1, Division 2 locations.




    ★★★★商品說明★★★★

    Armored Cable
     

    AirGuard 600 V

    PRYSMIAN CABLES & SYSTEMS
    XLP insulation
    High-strength Airbag layer
    PVC jacket
     

    SPECIFICATIONS
    1. CONDUCTOR:
    Class B Compact concentric strand soft-drawn annealed copper per ASTM
    2. INSULATION:High dielectric strength Cross-Linked Polyethylene (XLP) insulation to ICEA S-95-658/NEMA WC70 and UL 44 Type XHHW-
    3. GROUNDING CONDUCTORS: Bare stranded copper conductor, one in each interstice, per UL, ICEA and ASTM
    4. ASSEMBLY:Phase identified conductors cabled with fillers and grounding conductor per specification, forming a firm and cylindrical cable core
    5. MECHANICAL PROTECTION: High-strength and high-crush-resistant Airbag layer extruded over the core assembly
    6. JACKET:Sunlight-resistant Polyvinyl Chloride (PVC) jacket
    7. STANDARDS: Listed Type XHHW-2 singles. Passes the IEEE 1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests
    8. AMPACITY: Based on ambient temperature of 30°C (86°F) and 90°C conductor rating per NEC Table 310.16 for not more than three current carrying conductors in raceway,
    cable, or earth
    9. TEMPERATURE: 90°C
    10.VOLTAGE: 600 V
     

    APPLICATIONS
    For installation in wet and dry locations in accordance with NEC. May be directly buried or embedded in concrete. For installation on cable trays, troughs, metal racks, aerial
    installation and continuous rigid cable supports in accordance with NEC. Suitable for variable frequency drive applications (VFD). Suitable for vertical riser applications.
    Suitable for Class 1, Division 2 locations.
    AIRGUARD 600 V