    首頁 > > An-Armor Cable 1 金屬鎧裝電纜

    A-NORTECK XLP/Aluminum Armor/PVC 90ºC, UL 600 V, CSA 1 kV Three Conductor XLPE/PVC 3芯波浪狀鋁管鎧裝控制電纜
    看原圖
    5259025




    商品編號: A-7XK-0803AJ

    A-NORTECK XLP/Aluminum Armor/PVC 90ºC, UL 600 V, CSA 1 kV Three Conductor XLPE/PVC 3芯波浪狀鋁管鎧裝控制電纜


    For use in power circuits in industrial plants, commercial buildings, and central and substation utility applications. May be installed in trays, racks, hangers, etc.,
    eliminating the need for conduit. Suitable for indoor and outdoor installation. May be used in Class I and II, Div 2 locations.




    ★★★★商品說明★★★★

    Armored Cable
    Norteck (UL and CSA)

    600 V Three Conductor

    Aluminum interlocked armor
    XLP insulation
    Inner and outer PVC jackets
    UL 600 V, CSA 1 kV


    SPECIFICATIONS
    1. CONDUCTOR:
    Class B stranded, bare, annealed copper per ASTM B3 and B8
    2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-95-658 (NEMA WC70), Type RHH/RHW-2 requirements of UL 44 and RW90 requirements of CSA. Color coding is
    Method 1, Table E-2
    3. ASSEMBLY: The insulated conductors are cabled with a single uninsulated ground wire and fillers to make round
    4. INNER JACKET:Black, sunlight-resistant Polyvinyl Chloride (PVC). Jacket meets low acid gas requirements of CSA C22.2 No. 0.3
    5. ARMOR: Aluminum-interlocked
    6. OVERALL JACKET:Black, sunlight-resistant polyvinyl chloride (PVC) applied overall per ICEA, jacket meets low acid gas requirements of CSA C22.2 No. 0.3
    7. STANDARDS: Cables meet UL 1685 and IEEE1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests, and are marked "for CT use". Cables also meet
    CSA -40°C cold impact and bend test. Individual conductors UL Listed Type RHH/RHW-2 per UL 44 and listed CSA Type RW90. Completed cables listed Type MC per UL 1569 and
    CSA Type Teck 90 per CSA C22.2 No. 131
    8. AMPACITY: Based on not more than three conductors in raceway or cable or earth based on an ambient temperature of 30°C per 2008 NEC table 310.16
    9. TEMPERATURE:90°C


    APPLICATIONS
    For use in power circuits in industrial plants, commercial buildings, and central and substation utility applications. May be installed in trays, racks, hangers, etc.,
    eliminating the need for conduit. Suitable for indoor and outdoor installation. May be used in Class I and II, Div 2 locations.