| UT-141C-25-TP/DE25141 |
Semi-Rigid Coaxial Cable |
| MECHANICAL CHARACTERISTICS | | |
Outer Conductor Diameter, inch (mm) | 0.141+0.002/-0.001 (3.581+0.0508/-0.0254) |
Dielectric Diameter, inch (mm) | 0.117 (2.972) |
Center Conductor Diameter, inch (mm) | 0.064+/-0.001 (1.626+/-0.0254) |
Maximum Length, feet (meters) | 20 (6.1) |
Minimum Inside Bend Radius, inch (mm) | 0.188 (4.775) |
Weight, pounds/100 ft. (kg/100 meters) | 3.85 (5.73) |
| ELECTRICAL CHARACTERISTICS | | |
Impedance, ohms | 25+/-1.0 |
Frequency Range GHz | DC-29 |
Velocity of Propagation % | 70 |
Capacitance, pF/ft. (pF/meter) | 58 (190.4) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level | Frequency | Insertion Loss | Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz | 0.10 (0.33) 0.15 (0.48) 0.35 (1.15) 0.52 (1.70) 0.78 (2.56) | 311.3 217.1 91.8 62.4 41.8 |
Corona Extinction Voltage, VRMS @ 60 Hz | 1000 |
Voltage Withstand, VRMS @ 60 Hz | 2000 |
| ENVIRONMENTAL CHARACTERISTICS | | |
Outer Conductor Integrity Temperature, Deg Celsius | 175 |
Maximum Operating Temperature, Deg Celsius | 150 |
|
Outer Conductor | Tin plated Copper |
Dielectric | PTFE |