| UT-070C-10 |
Semi-Rigid Coaxial Cable |
| MECHANICAL CHARACTERISTICS | | |
Outer Conductor Diameter, inch (mm) | 0.070 +/- 0.001 (1.778 +/- 0.025) |
Dielectric Diameter, inch (mm) | 0.05 (1.27) |
Center Conductor Diameter, inch (mm) | 0.0403 +/- 0.0005 (1.0236 +/- 0.0127) |
Maximum Length, feet (meters) | 20 (6.1) |
Minimum Inside Bend Radius, inch (mm) | 0.125 (3.175) |
Weight, pounds/100 ft. (kg/100 meters) | 1.28 (1.91) |
| ELECTRICAL CHARACTERISTICS | | |
Impedance, ohms | 10 +/- 2.0 |
Frequency Range GHz | DC - 58 |
Velocity of Propagation % | 70 |
Capacitance, pF/ft. (pF/meter) | 145 (475) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level | Frequency | Insertion Loss | Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz | 0.51 (1.16) 0.72 (1.64) 1.63 (3.72) 2.33 (5.31) 3.35 (7.64) | 43.2 30.5 13.5 9.4 6.6 |
Corona Extinction Voltage, VRMS @ 60 Hz | 500 |
Voltage Withstand, VRMS @ 60 Hz | 1000 |
| ENVIRONMENTAL CHARACTERISTICS | | |
Outer Conductor Integrity Temperature, Deg Celsius | 150 |
Maximum Operating Temperature, Deg Celsius | 125 |
|
Outer Conductor | COPPER |
Dielectric | PTFE |
Center Conductor | SPC |
|
 |