    BLACKBOX-EYN770A-RL-1000  CAT6a 650-MHz F/UTP Solid Bulk Cable, PVC CMR, Blue, 1000-ft. (304.8-m)  鋁箔隔離 CAT-6a 網路線
    看原圖
    5230916




    商品編號: BLACKBOX-EYN770A-RL-1000

    BLACKBOX-EYN770A-RL-1000 CAT6a 650-MHz F/UTP Solid Bulk Cable, PVC CMR, Blue, 1000-ft. (304.8-m) 鋁箔隔離 CAT-6a 網路線


    Delivers channel performance beyond CAT6a standards.

    相關商品

    Product SKU
    CAT6a 650-MHz F/UTP Solid Bulk Cable, PVC CMR, Blue, 1000-ft. (304.8-m) EYN770A-RL-1000
    CAT6a 650-MHz F/UTP Bulk Cable, 23 AWG, Solid, 4-Pair, Plenum CMP, Blue, 1000-ft. (304.8-m) EYN771A-RL-1000



    ★★★★商品說明★★★★

    Description

    CAT6a 650-MHz F/UTP Bulk Cable, 23 AWG, Solid, 4-Pair, Plenum CMP, Blue, 1000-ft. (304.8-m)


    Quick Facts

  3. Use with Black Box® CAT6a components for a 10GBASE-T channel.
  4. Tested up to 650 MHz.
  5. Foil shield construction virtually eliminates alien crosstalk.
  6. Guaranteed for life!

  7.  

    Further Details

  8. A center isolation member maintains pair separation for optimal NEXT performance.
  9. Supports IEEE 802.3 and 10GBASE-T, and TIA 568-C.2. ETL tested.
  10. Construction: Internal separator, FEP insulation, dielectric tape, drain wire, aluminum/Mylar® tape.
  11. Smaller outside diameter than normal; CAT6a UTP.
    NOTE: Also available in PVC.
     
  12. Technical Specifications for CAT6a 650-MHz F/UTP Bulk Cable, 23 AWG, Solid, 4-Pair, Plenum CMP, Blue, 1000-ft. (304.8-m):

    ACRF — 37.8 dB at 100 MHz; 29.8 dB at 250 MHz; 26.9 dB at 350 MHz; 20.8 dB at 500 MHz; 21.5 dB at 650 MHz (previously referred to as equal level far end crosstalk (ELFEXT)
    Bend Radius —1.29" (33 mm)
    Conductors —4-pair, 23 AWG, solid copper
    Construction —Internal separator, FEP insulation, dielectric tape, drain wire, aluminum/Mylar tape
    Insertion Loss (dB/100 m) — 18.6 at 100 MHz; 43.8 at 500 MHz; 50.6 at 650 MHz
    Insulation —Fluoropolymer (FEP)
    Jacket — Low-smoke, flame-retardant LS0H/PVC
    NEXT — 45.3 dB at 100 MHz; 39.3 dB at 250 MHz; 37.1 dB at 350 MHz; 34.8 dB at 500 MHz; 33.1 dB at 650 MHz
    Outside Diameter — 0.283" (7.3 mm)
    PS-AACRF — 48.2 dB at 100 MHz; 40.2 dB at 250 MHz; 37.3 dB at 350 MHz; 34.2 dB at 500 MHz; 31.9 dB at 650 MHz
    PS-ACRF — 34.8 dB at 100 MHz; 18.5 dB at 650 MHz
    PS-ANEXT — 42.5 dB at 100 MHz; 66.5 dB at 250 MHz; 64.3 dB at 350 MHz; 62.0 dB at 500 MHz; 60.3 dB at 650 MHz
    PS-NEXT — 43.3 dB at 100 MHz; 37.3 dB at 250 MHz; 35.1 dB at 350 MHz; 32.8 dB at 500 MHz; 31.1 dB at 650 MHz
    Return Loss (dB/100 m) — 21.1 at 100 MHz; 16.5 at 500 MHz; 15.7 at 650 MHz
    RoHS — Yes
    Standards — IEEE 802.an; TIA 568-C.2; UL®, ETL Tested
    Weight — Not on reel: 48.3 lb. (21.9 kg)
     
    NOTE: Also available in PVC.
     


    ★★★★商品規格描述★★★★

    Black Box Explains…Augmented Category 6 (CAT6a) over F/UTP. .

    CAT6a is a 10-Gigabit Ethernet (10-GbE) over copper standard. Its requirements are covered in ANSI/TIA-568-C.2 (Balanced Twisted-Pair Telecommunications Cabling and Components Standard) published in August 2009. The standard defines 10-Gigabit data transmission over a 4-connector twisted-pair copper cable for a distance of 100 meters on CAT6a copper cabling. This ensures that the system is ready to support IEEE 802.3an, the IEEE standard for 10GBASE-T, which specifies using Class E-augmented cable.

    CAT6a extends electrical specifications from 250 MHz to 500 MHz. It also features Power-Sum Alien Crosstalk (PS-ANEXT) to 500 MHz. Alien Crosstalk (ANEXT) is a coupled signal in a disturbed pair arising from a signal in a neighboring cable. To virtually eliminate the problem of ANEXT, CAT6a F/UTP cable is used. The F indicates an outer foil shield that eliminates PS-ANEXT. When security is an issue, CAT6a is a good choice because it doesn’t emit signals. In addition, CAT6a F/UTP cable works well in noisy environments with a lot of EMI.